![cannon printer ir adv c5235 cannon printer ir adv c5235](https://www.worldclassink.com/fullaccess/cartridgeimages/sl450/Canon-GPR-31-Value-Pack.jpg)
NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
![cannon printer ir adv c5235 cannon printer ir adv c5235](https://oip.manual.canon/USRMA-0068-zz-CS-enGB/contents/images/book_images/b_drv_pw14_01_C.gif)
Check for open circuit inside the Fixing Assembly and any disconnection of the connector. Go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR and then turn OFF and then ON the power. Description: Abnormal detection during paper feedingĭuring print control, Sub Thermistor detects 70 deg C or less from the target temperature for 5 sec.Check connection of the Connectors (Thermistor Connector and AC Connector). Description: Error detected when the Heater is ONĪfter the Heater was turned ON, Main Thermistor 2, Sub Thermistor 1 or Sub Thermistor 2 detects 21 deg C or more and 50 deg C or less for 3 sec.Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN if the not working properly, replace the fan. If it’s at abnormally high temperature, do not turn on the power before replacing the Film Unit. If the detected temperature of the Thermistor is less than the abnormal high temperature specified for Thermistor, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR and then turn OFF and then ON the power. Hardware detects abnormal high temperature of the Thermistor (Main Thermistor 1: 264 deg C, Main Thermistor 2: 265 deg C, Sub Thermistor 1, 2: 280 deg C) for 400 msec consecutively. Description: High temperature error detected by hardware.Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN if not working properly, replace the fan. If it’s 275 deg C or more, do not turn on the power before replacing the Film Unit. Go through the following: DISPLAY > ANALOG > FIX-E2 or DISPLAY > ANALOG > FIX-E3 if it’s less than 275 deg C, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR and then turn OFF and then ON the power. Sub Thermistor 1, 2 (TH1) detects 275 deg C or more for 0.2 sec. Description: Abnormal high temperature in Sub Thermistor 1, 2.It it’s 260 deg C or more, do not turn on the power before replacing the Film Unit. Go through the following: DISPLAY > ANALOG > FIX-C, or DISPLAY > ANALOG > FIX-E if it’s less than 260 deg C, go through the following to clear the error: COPIER>FUNCTION>CLEAR>ERR and then turn OFF/ ON the power. Main Thermistor 1, 2 (TH1) detects 260 deg C or more for 0.2 sec. Description: Abnormal high temperature in Main Thermistor 1, 2.